Error 8BAT_COCP2VanMoof S3 / X3

VanMoof Error 8 on your S3 or X3: charging current too high

Error 8 is called BAT_COCP2: Charge Over Current Protection 2. While charging, the battery management system measured more current than permitted and stopped charging. The starting point is the charger itself: a non-original or faulty adapter is a known source of this fault. If the code stays with a good charger, the investigation moves on to the charging port and the BMS.

Try this yourself first

  1. Connect the original VanMoof charger instead of a universal adapter.
  2. Look into the charging port with a torch: if there's dirt or moisture in it, let the bike dry out first. Don't insert anything to clean it.
  3. If the code also comes back with the original charger, have it checked and don't keep charging in the meantime.

Didn't work, or does the message come back? Then we'll take a look.

Symptoms

  • The display shows Error 8 as soon as you connect the charger
  • Charging stops after a short time
  • The battery doesn't charge fully
  • The charger or charging port gets unusually warm

Possible causes

  • A non-original charger with too high a charging current
  • A faulty charger or charging cable
  • Dirt or damage in the charging port

How VanFoom fixes Error 8

  1. 1Measuring the charger and the charging cable
  2. 2Inspecting and cleaning the charging port and the contact pins
  3. 3Replacing the charger, charging port or BMS part with original VanMoof parts
  4. 4Full charge test before handover

In the meantime, don't keep charging with an adapter that gives this code. Usually ready within 7 working days.

Error 8? We'll fix it.

Book your repair online or give us a call. From S2 to S6, every error code, every part, with genuine VanMoof parts and a warranty.