Error 49MOTOR_CURRENT_ERRVanMoof S3 / X3

Error 49 on your VanMoof S3 or X3: motor current reading is off

Error 49 is called MOTOR_CURRENT_ERR: the calculated current offset of the motor deviates from the default value. The motor control calibrates itself at start-up, and that calibration doesn't come out where it's expected. It's an early warning about the drive: the bike often still rides, but the reading is no longer correct.

Symptoms

  • The display shows Error 49
  • Assistance feels different from normal
  • The stated range or consumption doesn't add up
  • Otherwise, the bike rides as usual

Possible causes

  • A deviating current sensor in the motor control
  • Early wear in the motor
  • A connection with too much contact resistance

How VanFoom fixes Error 49

  1. 1Reading out the calibration values and the error history
  2. 2Current measurement on the motor under load
  3. 3Recalibration, or repair of the motor control with genuine parts
  4. 4Test ride and check of the assistance curve

You can usually keep riding with this, but have it checked before it turns into a real motor fault.

Error 49? We'll fix it.

Book your repair online or give us a call. From S2 to S6, every error code, every part, with genuine VanMoof parts and a warranty.