Error 49MOTOR_CURRENT_ERRVanMoof S3 / X3
Error 49 on your VanMoof S3 or X3: motor current reading is off
Error 49 is called MOTOR_CURRENT_ERR: the calculated current offset of the motor deviates from the default value. The motor control calibrates itself at start-up, and that calibration doesn't come out where it's expected. It's an early warning about the drive: the bike often still rides, but the reading is no longer correct.
Symptoms
- The display shows Error 49
- Assistance feels different from normal
- The stated range or consumption doesn't add up
- Otherwise, the bike rides as usual
Possible causes
- A deviating current sensor in the motor control
- Early wear in the motor
- A connection with too much contact resistance
How VanFoom fixes Error 49
- 1Reading out the calibration values and the error history
- 2Current measurement on the motor under load
- 3Recalibration, or repair of the motor control with genuine parts
- 4Test ride and check of the assistance curve
You can usually keep riding with this, but have it checked before it turns into a real motor fault.
Error 49? We'll fix it.
Book your repair online or give us a call. From S2 to S6, every error code, every part, with genuine VanMoof parts and a warranty.